Trident HD Generator Board
Low-kVp generator board for specimen radiography - includes exposure calibration.
Description
Replacement generator control board for the Hologic Trident HD specimen radiography cabinet. Calibrated for low-dose specimen imaging at 20-35 kVp. Includes exposure repeatability test report.
What ships with this part
- Functional bench-test report against OEM specification
- 90-day parts-and-labor warranty (extendable on detectors and tubes)
- OEM part number reference and compatibility confirmation
- Same-day shipping for in-stock orders placed before 2pm Pacific
- kV / mAs calibration verification report at installed values
- Reusable shipping crate with prepaid return label for the failed unit
Available conditions
Pulled from a deinstalled system, fully tested and reconditioned to OEM specification by our biomedical team. All wear components replaced where applicable.
Ships as part of our exchange program - the certified replacement leaves Lake Forest first and your failed unit returns in the same crate. Lower cost than buying outright.
Frequently asked questions
Is the Trident HD Generator Board OEM, OEM-equivalent, or aftermarket?
+
Available as Refurbished or Exchange. Refurbished units are pulled from working deinstalled systems and brought back to OEM specification by our biomedical team. Every unit is bench-tested before shipment - we do not ship parts that do not meet spec.
What systems is ARR-GEN-TRD-100 compatible with?
+
This part is qualified for Trident HD. If you have a non-standard software revision or a system with a custom configuration, share your serial number with our parts desk and we will confirm fit before shipment so there are no surprises during installation.
Is calibration required after installation?
+
Yes. Any generator board replacement requires kV / mAs calibration to your specific tube and detector chain. ARRAD provides the calibration as part of a turnkey install. If your in-house biomed team handles installation, we ship the calibration procedure and test report alongside the board.
What warranty comes with the part?
+
Standard 90-day parts-and-labor warranty from receipt. Extended warranty coverage is available on detectors and X-ray tubes - typically 12 months parts coverage with a discounted exchange option if the unit fails inside the warranty window. Ask the parts desk when you quote.
Do you provide installation support?
+
Yes. ARRAD field engineers install this part as part of a service visit anywhere in the continental US, with same-day response in Southern California and 24-48 hour dispatch elsewhere. For mammography detectors, tubes and generator boards we strongly recommend ARRAD installation so calibration and the regulatory documentation are kept current.
Specifications
- kVp Range
- 20-35 kVp
- mAs Range
- 1-100 mAs
- Compatibility
- Trident HD
- Warranty
- 90 days
Related parts
Trident HD X-Ray Tube Assembly
Fixed-anode X-ray tube for the Hologic Trident HD specimen radiography cabinet.
Flat Panel DetectorsTrident HD Specimen Radiography Detector
Integrated flat panel detector module for the Hologic Trident HD specimen radiography cabinet.
Ready to Modernize Your Imaging?
Whether you're replacing a legacy system, opening a new imaging center or just need urgent service - an ARRAD specialist is ready to help.